DATEXEL srl - Via monte Nero, 40/B
21049 - Tradate (VA) - Italy
|
|
Tel. +39 (0)331 841070
Fax +39 (0)331 841950
www.datexel.it
- [email protected]
|
|

|
Trasmettitori di Temperatura e Segnale
Serie SMART
SMART Series: Temperature and Signal
Transmitters and Converters
|
DAT
2015
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 4 a 20 mA 2 fili
Montaggio
su Barra DIN
Datasheet
ED.0406R02 
|
PC
Programmable
RTD,
Res, Pot, Tc, V, mA Input
Linearised
4
to 20 mA 2 wires programmable Output
DIN
Rail Mounting
Datasheet
ED.1006R02
|
|
DAT
2015 IS
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc
Linearizzato
Certificato
ATEX Ex ia IIC
Uscita
programmabile da 4 a 20 mA 2 fili
Montaggio
su Barra DIN
Datasheet
ED.0706R03 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc Input
Linearised
ATEX
Ex ia IIC certified
4
to 20 mA 2 wires programmable Output
DIN
Rail Mounting
Datasheet
ED.0207R02
|
|
DAT
2015 IS/HT
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc
Linearizzato
Certificato
ATEX Ex ia IIC
Temperatura
Operativa fino a 85 °C
Uscita
programmabile da 4 a 20 mA 2 fili
Montaggio
su Barra DIN
Datasheet
ED.0706R03 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc Input
Linearised
ATEX
Ex ia IIC certified
Operative
temperature up to 85 °C
4
to 20 mA 2 wires programmable Output
DIN
Rail Mounting
Datasheet
ED.0207R02
|
|
DAT
2115
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 0 a 20 mA , da 0 a 10 V
Montaggio
su Barra DIN
Datasheet
ED.0406R02 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
0
to 20 mA , 0 to 10 V programmable Output
DIN
Rail Mounting
Datasheet
ED.1106R02
|
|
DAT
2115/SEL
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 0 a 20 mA , da 0 a 10 V
Comando
disabilitazione uscita
Montaggio
su Barra DIN
Datasheet
ED.0406R02 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
0
to 20 mA , 0 to 10 V programmable Output
Command
of Enable / Disable Output
DIN
Rail Mounting
Datasheet
ED.1106R02
|
|
DAT
4035
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 4 a 20 mA 2 fili
Isolamento
galvanico
Montaggio
su Barra DIN
Datasheet
ED.0406R02 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
4
to 20 mA 2 wires programmable Output
Galvanic
isolation
DIN
Rail Mounting
Datasheet
ED.1006R02
|
|
DAT
4035 IS
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc
Linearizzato
Certificato
ATEX Ex ia IIC
Isolamento
galvanico
Uscita
programmabile da 4 a 20 mA 2 fili
Montaggio
su Barra DIN
Datasheet
ED.0706R02 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc Input
Linearised
ATEX
Ex ia IIC certified
Galvanic
isolation
4
to 20 mA 2 wires programmable Output
DIN
Rail Mounting
Datasheet
ED.0207R02
|
|
DAT
4035 IS/HT
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc
Linearizzato
Certificato
ATEX Ex ia IIC
Temperatura
Operativa fino a 85 °C
Isolamento
galvanico
Uscita
programmabile da 4 a 20 mA 2 fili
Montaggio
su Barra DIN
Datasheet
ED.0706R02 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc Input
Linearised
ATEX
Ex ia IIC certified
Operative
temperature up to 85 °C
Galvanic
isolation
4
to 20 mA 2 wires programmable Output
DIN
Rail Mounting
Datasheet
ED.0207R02
|
|
DAT
4135
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 0 a 20 mA, da 0 a 10 V
Isolamento
galvanico
Montaggio
su Barra DIN
Datasheet
ED.0406R02 
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
0
to 20 mA , 0 to 10 V programmable Output
Galvanic
isolation
DIN
Rail Mounting
Datasheet
ED.1106R02
|
|
DAT
4135/SEL
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 0 a 20 mA , da 0 a 10 V
Comando
disabilitazione uscita
Isolamento
galvanico
Montaggio
su Barra DIN
Datasheet
ED.0406R02
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
0
to 20 mA , 0 to 10 V programmable Output
Command
of Enable / Disable Output
Galvanic
isolation
DIN
Rail Mounting
Datasheet
ED.1106R02
|
|
DAT
4135/AC
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 0 a 20 mA , da 0 a 10 V
Alimentazione
90..250 Vac
Isolamento
galvanico
Montaggio
su Barra DIN
Datasheet
ED.0606R03
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
0
to 20 mA , 0 to 10 V programmable Output
90..250
Vac Power Supply
Galvanic
isolation
DIN
Rail Mounting
Datasheet
ED.1106R02
|
|
DAT
4235
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile ± 20 mA , ± 10 V
Isolamento
galvanico
Montaggio
su Barra DIN
Datasheet
ED.0606R02
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
±
20 mA , ± 10 V programmable Output
Galvanic
isolation
DIN
Rail Mounting
Datasheet
ED.1106R02
|
|
DAT
4235 IS
|
Programmabile
da PC
Ingresso
RTD, Res, Pot, mV, Tc, V, mA
Linearizzato
Uscita
programmabile da 0 a 20 mA , da 0 a 10 V
Doppia
soglia di Allarme a Relé
Certificato
ATEX [ Ex ia ] IIC -
[ Ex iaD ]
Montaggio
su Barra DIN
Datasheet
ED.0506R04
|
PC
Programmable
RTD,
Res, Pot, mV, Tc, V, mA Input
Linearised
0
to 20 mA , 0 to 10 V programmable Output
Two
Relays Alarm Thresholds
ATEX
[ Ex ia ] IIC - [ Ex iaD ] Certified
DIN
Rail Mounting
Datasheet
ED.0506R03
|
|